The Bombardier ALP-45DP is a dual-mode locomotive used by NJ Transit to provide direct service from the unelectrified portions of its network to New York Penn Station.
Controls
Control desk
HeadlightSwitch
The headlight switch. Ranges from -1 to 1.
DitchLightsSwitch
The model position for the ditch lights switch. Ranges from -1 to 1.
DitchLights
The ditch lights click toggle, also operated by the J key. 0 = off, 1 = on.
CabLightSwitch
The model position for the cab light switch. Ranges from -1 to 1.
CabLight
The cab light click toggle, also operated by the L key. 0 = off, 1 = on.
InstrumentLightsSwitch
The model position for the instrument lights switch. Ranges from -1 to 1.
InstrumentLights
The instrument lights click toggle, also operated by the I key. 0 = off, 1 = on.
DeskLightSwitch
The model position for the desk light switch. Ranges from -1 to 1.
DeskLight
The desk light click toggle, also operated by the Ctrl+L key. 0 = off, 1 = on.
VirtualHorn
The horn plunger, also operated by the Spacebar. Plays the beginning of the horn sequence.
Horn
Plays the continuous horn sequence.
FaultReset
The fault reset button.
ThrottleAndBrake
The combined power and brake handle.
Regulator
The true throttle value used by the physics model.
DynamicBrake
The true dynamic braking value used by the physics model.
Reverser
The reverser lever. -1 = reverse, 0 = neutral, 1 = forward.
WipersSwitch
The model position for the wipers switch. Ranges from -1 to 1.
VirtualWipers
The wipers click toggle, also toggled with the V key.
Wipers
When set to 1, the wipers move and complete one cycle. Resets back to 0 after the animation completes.
SanderSwitch
The model position for the sander switch. Ranges from -1 to 1.
VirtualSander
The sander click toggle, also operated by the X key.
Sander
The true sander state used by the physics model.
BellSwitch
The model position for the bell switch. Ranges from -1 to 1.
VirtualBell
The bell click toggle, also operated by the B key.
Bell
The true bell state used by the physics model.
HandbrakeSwitch
The handbrake switch. Ranges from -1 to 1.
PantographSwitch
The pantograph switch. Ranges from -1 to 1.
VirtualBrake
The player's Expert Mode train brake control. Ranges from 0 to 1.
Value | Meaning |
---|---|
1.0 | Emergency |
0.8 | Handle off |
0.6 | Service |
0.4 | Lap |
0.2 | E-Hold |
0.0 | Release |
TrainBrakeControl
The true train brake control used by the physics model. Ranges from 0 to 1.
VirtualEngineBrakeControl
The player's independent brake control. Ranges from 0 to 1.
EngineBrakeControl
The true independent brake control used by the physics model. Ranges from 0 to 1.
AWSReset
The safety systems acknowledge button.
Indicators
SpeedH
The hundreds digit on the speedometer display. -1 hides the digit.
SpeedT
The tens digit on the speedometer display. -1 hides the digit.
SpeedU
The ones digit on the speedometer display. -1 hides the digit.
ACSES_SpeedH
The hundreds digit on the ACSES speed limit display. -1 hides the digit.
ACSES_SpeedT
The tens digit on the ACSES speed limit display. -1 or 0 hides the digit.
ACSES_SpeedU
The ones digit on the ACSES speed limit display. The only valid values are 0, 5, and -1 (which hides the digit).
ACSES_SignalDisplay
The signal speed limit display.
Value | Meaning |
---|---|
8 | Stop |
7 | Restricting |
6 | Approach |
5 | 30 mph |
4 | 45 mph |
3 | 60 mph |
2 | 80 mph |
1 | MAS |
All other values extinguish all lamps.
ATC_Node
The ATC indicator light.
ATC_CutOut
The ATC cut out light.
ACSES_Node
The ACSES indicator light.
ACSES_CutOut
The ACSES cut out light.
ACSES_CutIn
The ACSES cut in light.
Sounds
ACSES_Alert
Plays a continuous, rapid beep-beep sound.
ACSES_AlertIncrease
Plays a short upgrade tone.
ACSES_AlertDecrease
Plays a short downgrade tone.
ExteriorSounds
Plays some background noise.
VirtualRPM
Plays the range of diesel engine sounds.
Miscellaneous
VirtualEmergencyBrake
The emergency brake lever.
EmergencyBrake
The true emergency brake state used by the physics model.
FuelPump
The fuel pump indicator light.
HEP
The HEP switch. The default state is 1 (on).
UnitT
UnitU
Sets the digits of the unit number in the center pillar. The "45-" digits at the beginning of the number are static textures.
WindowLeft
WindowRight
The positions of the openable windows, from 0 (closed) to 1 (open).
Keyboard shortcuts
AWSWarnCount
The exclamation mark indicator on the HUD.
ATC
The Ctrl+F ATC on/off toggle. The default state is 0.
ACSES
The Ctrl+D ACSES on/off toggle. The default state is 0.
DoorsManual
The Ctrl+Shift+T manual doors on/off toggle. The default state is 0.
DoorsManualClose
The Ctrl+T manual doors close button. Value resets to 0 after one frame.
WipersInt
The Ctrl+V interminnent wipers toggle. The default state is 0.
VirtualStartup
The Z engine start/stop toggle. The default state is 1 (run).
PowerSwitch
The Y change power button. Value resets to 0 after one frame.
PowerSwitchAuto
The Ctrl+Y automatic power change toggle. The default state is 0 (off).
Destination
Cycles up/down with the Ctrl+Shift+5 and Ctrl+Shift+6 keys.
Value | Destination |
---|---|
1 | Trenton |
2 | New York |
3 | Long Branch |
4 | Hoboken |
5 | Dover |
6 | Bay Head |
Model nodes
ditch_left
ditch_right
The ditch lights.
LightsYellow
LightsBlue
LightsGreen
The external brake indicator lights.
Lights
CabLight
The cab dome light.
DeskLight
The control desk light.
DitchLight_Left
DitchLight_Right
The ditch lights.
Animations
Pantograph
Raises the pantograph. The duration is 2 seconds.
Fans
Spins the exhaust fans.
Consist messages
10100
Communicates the currently displayed destination sign to the passenger coaches. The argument is the ID of the destination.
Emitters
Exhaust1
Exhaust2
Exhaust3
Exhaust4